forked from spinesystemspublic/documentation
Add diagnostics
This commit is contained in:
+130
-2
@@ -250,8 +250,6 @@ Then bonding itself:
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
```
|
```
|
||||||
|
|
||||||
|
|
||||||
## FBF
|
## FBF
|
||||||
|
|
||||||
### EX4500, EX4550
|
### EX4500, EX4550
|
||||||
@@ -326,3 +324,133 @@ interfaces {
|
|||||||
|
|
||||||
```
|
```
|
||||||
|
|
||||||
|
## Diagnostics
|
||||||
|
|
||||||
|
### SFP signal monitoring
|
||||||
|
|
||||||
|
If your SFP support DDMI, you can monitor the signal strength of the SFP. This is useful to see if the SFP is working properly or not.
|
||||||
|
|
||||||
|
```
|
||||||
|
admin@CORE> show interfaces diagnostics optics xe-0/0/0
|
||||||
|
Physical interface: xe-0/0/0
|
||||||
|
Laser bias current : 8.370 mA
|
||||||
|
Laser output power : 0.6260 mW / -2.03 dBm
|
||||||
|
Module temperature : 40 degrees C / 104 degrees F
|
||||||
|
Module voltage : 3.2510 V
|
||||||
|
Receiver signal average optical power : 0.4357 mW / -3.61 dBm
|
||||||
|
Laser bias current high alarm : Off
|
||||||
|
Laser bias current low alarm : Off
|
||||||
|
Laser bias current high warning : Off
|
||||||
|
Laser bias current low warning : Off
|
||||||
|
Laser output power high alarm : Off
|
||||||
|
Laser output power low alarm : Off
|
||||||
|
Laser output power high warning : Off
|
||||||
|
Laser output power low warning : Off
|
||||||
|
Module temperature high alarm : Off
|
||||||
|
Module temperature low alarm : Off
|
||||||
|
Module temperature high warning : Off
|
||||||
|
Module temperature low warning : Off
|
||||||
|
Module voltage high alarm : Off
|
||||||
|
Module voltage low alarm : Off
|
||||||
|
Module voltage high warning : Off
|
||||||
|
Module voltage low warning : Off
|
||||||
|
Laser rx power high alarm : Off
|
||||||
|
Laser rx power low alarm : Off
|
||||||
|
Laser rx power high warning : Off
|
||||||
|
Laser rx power low warning : Off
|
||||||
|
Laser bias current high alarm threshold : 100.000 mA
|
||||||
|
Laser bias current low alarm threshold : 0.000 mA
|
||||||
|
Laser bias current high warning threshold : 90.000 mA
|
||||||
|
Laser bias current low warning threshold : 0.100 mA
|
||||||
|
Laser output power high alarm threshold : 1.2580 mW / 1.00 dBm
|
||||||
|
Laser output power low alarm threshold : 0.1990 mW / -7.01 dBm
|
||||||
|
Laser output power high warning threshold : 1.0000 mW / 0.00 dBm
|
||||||
|
Laser output power low warning threshold : 0.2510 mW / -6.00 dBm
|
||||||
|
Module temperature high alarm threshold : 90 degrees C / 194 degrees F
|
||||||
|
Module temperature low alarm threshold : -5 degrees C / 23 degrees F
|
||||||
|
Module temperature high warning threshold : 85 degrees C / 185 degrees F
|
||||||
|
Module temperature low warning threshold : 0 degrees C / 32 degrees F
|
||||||
|
Module voltage high alarm threshold : 3.800 V
|
||||||
|
Module voltage low alarm threshold : 2.700 V
|
||||||
|
Module voltage high warning threshold : 3.700 V
|
||||||
|
Module voltage low warning threshold : 2.800 V
|
||||||
|
Laser rx power high alarm threshold : 1.0000 mW / 0.00 dBm
|
||||||
|
Laser rx power low alarm threshold : 0.0501 mW / -13.00 dBm
|
||||||
|
Laser rx power high warning threshold : 0.7943 mW / -1.00 dBm
|
||||||
|
Laser rx power low warning threshold : 0.0631 mW / -12.00 dBm
|
||||||
|
```
|
||||||
|
Which means:
|
||||||
|
|
||||||
|
First quickly go thru list of alarms and warnings, if you see any of them, you have a problem with SFP or fiber.
|
||||||
|
|
||||||
|
Second check values, to have estimation.
|
||||||
|
|
||||||
|
* Receiver signal average optical power : 0.4357 mW / -3.61 dBm
|
||||||
|
Means the signal is good, and the SFP is working properly. Usually signal should vary between " Laser rx power high warning threshold : 0.7943 mW / -1.00 dBm" and
|
||||||
|
"Laser rx power low warning threshold : 0.0631 mW / -12.00 dBm". Which means if it is below -12dBm or above -1dBm, you have a problem. Too low signal usually means either problem with SFP degradation or fiber attenuation(damaged?). Too high signal usually means too much light is coming to the receiver, which can be caused by too high power SFP TX on other side + too short fiber for such type of SFP, this might cause receiver burnout.
|
||||||
|
You might also watch out for "borderline" values, which are close to the threshold, this might indicate that you have a problem, but it is not critical yet.
|
||||||
|
|
||||||
|
* Laser bias current : 8.370 mA
|
||||||
|
Similar, you need to be within bounds set by "bias current".
|
||||||
|
|
||||||
|
Watch out also for SFP temperatures, if it is too high, it might indicate that SFP is overheating, and likely will degrade soon.
|
||||||
|
|
||||||
|
### Check inventory
|
||||||
|
|
||||||
|
Usually it is used to verify list of plugged in SFPs, but it also shows other hardware.
|
||||||
|
|
||||||
|
```
|
||||||
|
admin@CORE> show chassis hardware
|
||||||
|
Hardware inventory:
|
||||||
|
Item Version Part number Serial number Description
|
||||||
|
Chassis ZZZZ EX4500-40F
|
||||||
|
Routing Engine 0 REV 08 750-035702 ZZZZ EX4500-40F
|
||||||
|
FPC 0 REV 08 750-035702 ZZZZ EX4500-40F
|
||||||
|
CPU BUILTIN BUILTIN FPC CPU
|
||||||
|
PIC 0 BUILTIN BUILTIN 40x 1/10GE
|
||||||
|
Xcvr 0 REV 01 740-021308 I0512280053 SFP+-10G-SR
|
||||||
|
Xcvr 1 NON-JNPR CI151116245 SFP-T
|
||||||
|
Xcvr 2 REV 01 740-031980 F172JU01652 SFP+-10G-SR
|
||||||
|
Xcvr 3 REV 01 740-031980 F172JU01651 SFP+-10G-SR
|
||||||
|
Xcvr 4 REV 01 740-021308 I0512280054 SFP+-10G-SR
|
||||||
|
Xcvr 5 REV 01 740-031981 F172JU02038 SFP+-10G-LR
|
||||||
|
|
||||||
|
```
|
||||||
|
|
||||||
|
### New SFP not working
|
||||||
|
|
||||||
|
This might happen on Junipers, while they work with most of SFP, some might be not compatible.
|
||||||
|
|
||||||
|
If you plugged in new SFP and it is not working, you can check if it is recognized by the switch. Check by following commands:
|
||||||
|
|
||||||
|
```
|
||||||
|
show chassis hardware
|
||||||
|
show interfaces diagnostics optics **-0/0/0
|
||||||
|
show interface **-0/0/0 extensive
|
||||||
|
|
||||||
|
** should be replaced by interface name, for example xe-0/0/0, but you need to assume sometimes 1G, 10G not detected correctly, so you might need to check all possible types, like ge and xe.
|
||||||
|
```
|
||||||
|
|
||||||
|
|
||||||
|
For last command attention on lines like this:
|
||||||
|
|
||||||
|
```
|
||||||
|
Physical interface: xe-0/0/0, Enabled, Physical link is Up
|
||||||
|
|
||||||
|
Link-level type: Ethernet, MTU: 1514, LAN-PHY mode, Speed: 10Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled, Media type: Fiber
|
||||||
|
```
|
||||||
|
If physical link is Down it might also means SFP is non-standard, not detected correctly and not working.
|
||||||
|
Check also if Speed, Media type match specification.
|
||||||
|
|
||||||
|
### Packetloss
|
||||||
|
|
||||||
|
If you suspect packetloss on some link, juniper have nice "flood" ping commands.
|
||||||
|
```
|
||||||
|
admin@CORE> ping 10.0.252.2 count 1000 rapid
|
||||||
|
PING 10.0.252.2 (10.0.252.2): 56 data bytes
|
||||||
|
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
|
||||||
|
--- 10.0.252.2 ping statistics ---
|
||||||
|
1000 packets transmitted, 1000 packets received, 0% packet loss
|
||||||
|
round-trip min/avg/max/stddev = 0.572/2.286/13.992/2.207 ms
|
||||||
|
```
|
||||||
|
This will send 1000 packets as fast as possible, and will show you packetloss and RTT. While you can ignore RTT, as control plane dont have high priority, packetloss should not be present in any case.
|
||||||
Reference in New Issue
Block a user